02.12.2021
Hello, I suspect that there is an error in default parameters of the model of Five-phase permanent magnet synchronous motor with sinusoidal flux distribution. The mutual inductances are written as Lab...

Hello,

I suspect that there is an error in default parameters of the model of Five-phase permanent magnet synchronous motor with sinusoidal flux distribution.

The mutual inductances are written as Lab = -M + something (see help for this element), which is true for 3-phase motors where angle between phases is 120 degrees and cos(120) is -0.5.

For 5-phase machine the angle between phases is 72 degrees and cosine is positive. Therefore, this equation should be wrintten as Lab = M + something.

Of course, it is possible to invert M in the parameters' settings, but it is not done by the default.

 